Anritsu MT9083 Series Operation Manual page 64

Access master remote control
Table of Contents

Advertisement

Chapter 4 OTDR Commands
4.3.11 SOURce:PULSe Command
Syntax:
SOURce:PULSe<wsp><value>
Parameters:
<value>
Numeric format
Range: Integer PW value returned by querying available pulse width command.
Available pulse width values are dependant on current range/resolution settings.
Description:
Set current pulse width.
Example:
sour:puls 100
Response:
None
Errors:
(–200, "std_execGen, Test is Active")
(–224, "std_illegalParmValue, Invalid Parameter Value")
4.3.12 SOURce:PULSe? Command
Syntax:
SOURce:PULSe?
Parameters:
None
Description:
Query current pulse width.
Example:
sour:puls? --- 100<END>
Response:
value is current pulse width in nanoseconds (NS)
Errors:
None
4.3.13 SOURce:PULSe:ENHanced:AVAilable? Command
Syntax:
SOURce:PULSe:ENHanced:AVAilable?
Parameters:
None
Description:
Queries if the enhance mode is available for currently set pulse width.
Example:
sour:puls:enh:ava? --- 1<END>
Response:
Boolean value 1 or 0.
Errors:
None
4-12