Chapter 2 Before use
2-6
1.
Set the IP Address. The input setting range is 0.0.0.1 to
255.255.255.254.
Use the instrument's numeric keypad or the Left/Right/Up/Down
Arrow keys to input the numeric values. The default setting is
192.168.1.2.
2.
Set the IP Netmask.
The input setting range is 0.0.0.0 to 255.255.255.255 and the default
setting is 255.255.255.0.
3.
Set the Default Gateway.
The input setting range is 0.0.0.1 to 255.255.255.254 and the default
is None.
4.
Set the SCPI Port Number (TCP port).
The input setting range is 1 to 65535 and the default is 2288.
Press Accept (f1) after finishing the settings to close the Remote Setup
screen. When a connection is established, an icon indicating successful
connection is displayed in the screen Title Bar.
Figure 2.3-2 Remote control icon
After setting the IP Address of the ACCESS Master, also set the address