18) Remove the generator stator (15) along with the
CKP sensor (16).
Installation
Install the generator in the reverse order of removal. Pay
attention to the following points:
• Tighten the generator stator set bolts and CKP sensor
mounting bolts to the specified torque.
NOTE
Be sure the grommet (1) is set to the
generator cover.
Tightening torque
Generator stator set bolt (a): 11 N·m (1.1 kgf-m,
8.0 lb-ft)
CKP sensor mounting bolt (b): 6 N·m (0.6 kgf-m,
4.3 lb-ft)
Generator lead wire clamp bolt (c): 6 N·m (0.6 kgf-
m, 4.3 lb-ft)
(b)
16
15
I827H11A0033-01
(c)
(a)
I827H11A0034-01
• Degrease the tapered portion "A" of generator rotor
assembly and "B" of the crankshaft. Use
nonflammable cleaning solvent to wipe off oily or
greasy matter to make these surfaces completely dry.
• Fit the key (2) in the key slot on the crankshaft.
• Install the generator rotor assembly onto crankshaft.
"A"
• Hold the generator rotor with the special tool and
tighten the generator rotor nut to the specified torque.
Special tool
(A): 09930–44541 (Rotor holder)
Tightening torque
Generator rotor nut: 140 N·m (14.0 kgf-m, 101.0
lb-ft)
CAUTION
!
Make sure that the starter driven gear on the
crankshaft is fitted into the generator rotor
properly.
Charging System:
1J-7
2
"B"
I827H11A0019-01
(A)
I827H11A0020-01