Accelerating and Decelerating Constant Frequencies in the Analog Refer-
ences (+/- Speed)
The +/- speed function increments or decrements the frequency set in analog frequency reference d4-02 (+/-
Speed Limit) using two contact signal inputs.
To use this function, set One of the constants H1-01 to H1-10 (multi-function contact terminal inputs S3 to
S12 function selection) to 1C (Trim Control Increase command) and 1D (Trim Control Decrease command).
Be sure to allocate two terminals so that the Trim Control Increase command and Trim Control Decrease com-
mand can be used as a pair.
Related Constants
Con-
stant
Number
d4-02
Trim Control Increase/Decrease Command and Frequency Reference
The frequency references using Trim Control Increase/Decrease command ON/OFF operations are shown
below.
Frequency Reference
Trim Control Increase
Command Terminal
Trim Control Decrease
Command Terminal
Application Precautions
Trim Control Increase/Decrease command is enabled when speed reference > 0 and the speed reference is
from an analog input.
When the analog frequency reference value - d4-02 < 0, the frequency reference is set to 0.
If only the Trim Control Increase command or Trim Control Decrease command has been set for a multi-
function contact input terminal S3 to S12, operation error OPE03 (invalid multi-function input selected)
will occur.
-82
6
Name
Description
Display
+ - Speed limits Set the frequency to be add to or
subtracted from the analog fre-
quency reference as a percent,
taking the maximum output fre-
quency to be 100%.
+ - 加减速极限
Enabled when the increase (+)
speed command or decrease (-)
speed command is set for a multi-
function input.
Set Frequency
Reference
+ d4-02
ON
OFF
Change
Setting
Factory
during
Range
Setting
Opera-
V/f
tion
0 to
10%
No
A
100
Set Frequency
Reference
Set Frequency Command
- d4-02
OFF
ON
ON
ON
Control Methods
MEMO
Open
Open
BUS
V/f
Flux
Loop
Loop
Regis-
with
Vec-
Vector
Vector
ter
PG
tor
1
2
A
A
A
A
299H
OFF
OFF

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents