Name
Con-
stant
Display
Number
Stall pre-
0: Disabled (Runs as set. With
vention
a heavy load, the motor may
selection
stall.)
during run-
1: Deceleration time 1 (the
ning
deceleration time for the
L3-05
stall prevention function is
C1-02.)
2: Deceleration time 2 (the
运行中防失
deceleration time for the
速选择
stall prevention function is
C1-04.)
Stall pre-
Effective when L3-05 is 1 or 2.
vention
Set as a percentage of the
level dur-
Inverter rated current.
L3-06
ing running
Usually setting is not necessary.
The factory setting reduces the
运行中防止
set values when the motor
失速值
stalls.
Overvolt-
0: Disabled
age inhibit
1: Enabled
selection
Used to enable or disable the
function for inhibiting main cir-
cuit overvoltages by reducing
the regenerative torque limit
L3-11
according to the main circuit
overvoltage level.
OV 抑制功能
If this function is enabled,
选择
when the main circuit voltage
rises, operation will be per-
formed with the regenerative
torque less than the set value.
Overvolt-
Sets the main circuit voltage
age inhibit
level for which the regenerative
voltage
torque limit is restricted to 0.
level
Usually, there is no need to
L3-12
change this setting. If main cir-
cuit overvoltages occur even
OV 抑制电压
with the overvoltage inhibit
function enabled, reduce this
setting.
* 1. The setting range for flux vector and open-loop vector 2 controls is 0 to 2.
* 2. These values are for a 200 V Class Inverter. For a 400 V Class Inverter, double the values.
Reference Detection: L4
User constants for the reference detection function are shown in the following table.
Name
Con-
stant
Display
Number
Speed agree
Effective when "Desired fre-
detection
quency (ref/setting) agree 1,"
level
"Frequency detection 1," or
L4-01
"Frequency detection 2" is set
for a multi-function output.
频率检出值
Frequencies to be detected are
set in Hz units.
Setting
Factory
Description
Range
Setting
0 to 2
30 to
200
0 or 1
350 to
390
*2
Setting
Factory
Description
Range
Setting
0.0 to
400.0
Control Methods
Change
Open
during
V/f
Loop
Opera-
V/f
with
Vec-
tion
PG
tor
1
1
No
A
A
No
160%
No
A
A
No
0
No
No
No
A
380V
No
No
No
A
*2
Control Methods
Change
Open
during
V/f
Loop
Opera-
V/f
with
Vec-
tion
PG
tor
1
0.0 Hz
No
A
A
A
User Constant Tables
MEMO-
Open
BUS
Flux
Loop
Page
Regis-
Vec-
Vec-
ter
tor
tor
2
4-21
No
No
493H
6-49
4-21
No
No
494H
6-49
4-21
A
A
4C7H
6-27
7-3
4-21
A
A
4C8H
6-27
MEMO-
Open
BUS
Flux
Loop
Page
Regis-
Vec-
Vec-
ter
tor
tor
2
A
A
499H
6-50
5-
61