YASKAWA varispeed G7 CIMR-G7B series Instruction Manual page 165

General purpose inverter (advanced vector control)
Table of Contents

Advertisement

Name
Con-
Description
stant
Display
Number
Bias (termi-
Sets the input gain (level)
nal A3)
when 0 V is input.
H3-07
Set according to the 100%
端子 A3 偏置
value selected from H3-05.
Signal level
0: 0 to 10V
selection
1: -10V to 10V
(terminal A2)
2: 4 to 20 mA (9-bit input).
H3-08
Switch current and voltage
端子 A2 信号
input using the switch on the
选择
control panel.
Multi-func-
tion analog
Select multi-function analog
input (termi-
H3-09
input function for terminal
nal A2) func-
A2. Refer to the next table.
tion selection
端子 A2 设定
Gain
Sets the input gain (level)
(terminal A2)
when 10 V (20 mA) is input.
H3-10
Set according to the 100%
value for the function set for
端子 A2 增益
H3-09.
Bias
Sets the input gain (level)
(terminal A2)
when 0 V (4 mA) is input.
H3-11
Set according to the 100%
value for the function set for
端子 A2 偏置
H3-09.
Analog input
Sets primary delay filter time
filter time
constant in seconds for the
constant
H3-12
analog input terminal.
Effective for noise control
模拟量滤波
etc.
时间
Control Methods
Change
Setting
Factory
during
Range
Setting
Opera-
V/f
tion
-100.0
to
0.0%
Yes
A
+100.0
0 to 2
2
No
A
0 to 1F
0
No
A
0.0 to
100.0%
Yes
A
1000.0
-100.0
to
0.0%
Yes
A
+100.0
0.00 to
0.03
No
A
2.00
s
User Constant Tables
MEMO-
Open
Open
BUS
V/f
Loop
Flux
Loop
Regis-
with
Vec-
Vec-
Vec-
ter
PG
tor
tor
tor
1
2
A
A
A
A
416H
A
A
A
A
417H
A
A
A
A
418H
A
A
A
A
419H
A
A
A
A
41AH
A
A
A
A
41BH
Page
6-28
6-128
6-28
6-128
6-28
6-128
6-29
6-128
6-29
6-129
6-29
51
5-