Sequence Circuit Configuration
The brake ON/OFF sequence circuit configuration is shown below.
Inverter (Varispeed G7)
UP
S1
(Forward run)
DOWN
S2
(Reverse run)
HIGH/LOW
S6
(Multi-step speed reference 2)
SC
Note Design the sequence so that the holding brake contact is open when the sequence operation conditions are satisfied and the contact between M1 and M2
is closed (ON).
Make sure that the holding brake contact is closed when the emergency stop signal or Inverter fault contact output signal is ON.
Fig 6.85 Brake ON/OFF Sequence Circuit Configuration
Time Chart
The brake ON/OFF sequence time charts are shown in Figs. 6.86 and 6.87.
S1-SC
UP
High speed/
S6-SC
Low speed
Output frequency
Frequency detection 2
(H2-01 = 05)
M1-M2
Holding brake
operation
Note For variable speed operation by an analog signal, set to b1-01 = 1.
Fig 6.86 Brake ON/OFF Sequence Time Chart (V/f, V/f with PG, open-loop vector 1)
S1-SC
UP
High speed/
S6-SC
Low speed
Output frequency
During run 2
(H2-01 = 37)
M1-M2
Holding brake
operation
Note For variable speed operation by an analog signal, set to b1-01 = 1.
Fig 6.87 Brake ON/OFF Sequence Time Chart (Flux Vector)
Fault contacts
MA
MB
MC
M1
M2
Frequency
detection 2, 5 or
During run 2
OFF
ON
OFF
ON
d1-03
L4-01
0
ON
OPEN
CLOSE
OFF
ON
OFF
ON
d1-03
0
ON
OPEN
CLOSE

Using Inverters for Elevating Machines

Holding brake
auxiliary relay coil
UP
Safety
BR
circuit
DOWN
BR
Energizes the brake when ON
(250 VAC 1 A or less, 30 VDC
1 A or less)
d1-01 (Enabled when b1-01 = 0)
b4-01
DC injection braking
OFF
CLOSE
d1-01 (Enabled when b1-01 = 0)
b2-01
DC injection braking (Zero-speed control)
OFF
CLOSE
Time
Time
171
6-