Name
Con-
stant
Display
Number
Speed/torque
Set the delay time from input-
control
ting the multi-function input
switching
"speed/torque control
timer
change" (from On to OFF or
OFF to ON) until the control
is actually changed, in ms
units.
This function is enabled when
the multi-function input
d5-06
"speed/torque control
change" is set. In the speed/
控制切换时间
torque control switching
timer, the analog inputs hold
the values of when the
"speed/torque control
change" changes. Always be
sure to allow time for this
process to finish completely.
Rotation
0: Disabled
direction
1: Enabled
limit
Usually, use a setting of 1
operation
(enabled).
d5-07
selection
Be sure to enable this setting
when rotating the motor in
the same direction as the
旋转方向限制
speed limit (winding opera-
动作
tion).
* The factory setting will change when the control method is changed. The flux vector factory setting is given.
Field Weakening: d6
User constants for the field weakening command are shown in the following table.
Name
Con-
stant
Display
Number
Field weak-
Set the Inverter output volt-
ening level
age when the field weakening
command is input.
It is enabled when the field
d6-01
weakening command is set
for a multi-function input.
弱励磁值
Set the level as a percentage
taking the voltage set in the
V/f pattern as 100%.
Field
Set the lower limit in hertz of
frequency
the frequency range where
field control is valid.
The field weakening com-
d6-02
mand is valid only at frequen-
cies above this setting and
励磁频率
only when the speed is in
agreement with the current
speed reference.
Setting
Factory
Description
Range
Setting
0 to
1000
0 or 1
Setting
Factory
Description
Range
Setting
0 to
100
0.0 to
0.0 Hz
400.0
Control Methods
Change
Open
during
V/f
Loop
Opera-
V/f
with
Vec-
tion
PG
tor
1
0
No
No
No
No
1
No
No
No
No
Control Methods
Change
Open
during
V/f
Loop
Opera-
V/f
with
Vec-
tion
PG
tor
1
80%
No
A
A
No
No
A
A
No
User Constant Tables
MEMO-
Open
BUS
Flux
Loop
Page
Regis-
Vec-
Vec-
ter
tor
tor
2
A
A
29FH 6-128
No
A
2A6H 6-128
MEMO-
Open
BUS
Flux
Loop
Page
Regis-
Vec-
Vec-
ter
tor
tor
2
No
No
2A0H
-
No
No
2A1H
-
5-
31