YASKAWA varispeed G7 CIMR-G7B series Instruction Manual page 272

General purpose inverter (advanced vector control)
Table of Contents

Advertisement

Con-
stant
Number
b3-13
b3-14
b3-17
b3-18
b3-19
L2-03
L2-04
* 1. The factory setting will change when the control method is changed. The open-loop vector 1 control factory settings are given.
* 2. The factory setting depends on the Inverter capacity. The value for a 200 V Class Inverter of 0.4 kW is given.
-66
6
Name
Description
Display
Proportional
Sets the proportional gain (PI con-
gain of the
trol) of the speed estimator during
speed estimator
speed search taking the setting of
during speed
N4-08 to be equivalent to a setting
search
of 1.0.
Usually, there is no need to
change this setting. If, however,
速度推定比例增
the load inertia is large and over-
voltages occur during the search,
reduce this setting.
Rotation direc-
0: Disabled (operates with speci-
tion search
fied rotation direction)
selection
1: Enabled (operates with rota-
旋转方向搜索选
tion direction found by search)
Speed search
Sets the current level to retry a
retrial current
speed search as a percentage, tak-
level
ing the Inverter rated current as
100%.
搜索重试 I 值
Speed search
retrial detec-
Sets the time for detection in a
tion time
speed search retrial in units of
seconds.
速度搜索检出时
Number of
speed search
Sets the number of times that a
retrials
speed search can be retried.
速度搜索重试次
Min. baseblock
Sets the Inverter's minimum base-
time
block time in units of one second,
when the Inverter is restarted after
power loss ridethrough.
Sets the time to approximately 0.7
times the motor secondary circuit
time constant.
最小 BB 时间
When an overcurrent or overvolt-
age occurs when starting a speed
search or DC injection braking,
increase the set values.
Voltage recov-
Sets the time required to return
ery time
the Inverter output voltage to nor-
mal voltage at the completion of a
speed search, in units of one sec-
ond.
电压恢复时间
Sets the time required to recover
from 0 V to the maximum volt-
age.
Control Methods
Change
Setting
Factory
during
V/f
Range
Setting
Opera-
V/f
with
tion
PG
0.1 to
1.0%
No
No
No
2.0
0 or 1
1
No
A
A
0 to
150%
No
A
No
200
0.00 to
0.10 s
No
A
No
1.00
0 to 10
0
No
A
No
0.1 to
0.2 s
No
A
A
5.0
*2
0.0 to
0.3 s
No
A
A
5.0
*2
MEMO
Open
Open
BUS
Flux
Loop
Loop
Regis-
Vec-
Vector
Vector
ter
tor
1
2
No
No
A
19DH
A
No
A
19EH
A
No
A
1F0H
A
No
A
1F1H
A
No
A
1F2H
A
A
A
487H
A
A
A
488H