Error correction
Error message
14
Field numer
15
Length mask
16
Unknown mask
17
Missing ETB
18
Invalid character
19
Invalid statement
20
Invalid check digit
21
Invalid SC number
22
Invalid number of
digits
23
Check digit
calculation
24
Invalid extension
25
Offset sign
26
Offset value
27
Printhead
temperature
28
Cutter error
29
Invalid parameter
98
Cause
Received line number is invalid
at RS-232 and Centronics.
Invalid length of received mask
statement.
Transferred mask statement is
invalid.
No end of data found.
One res. several characters of
the text is res. are not available
in the selected font.
Unknown transferred data
record.
For check digit control the
entered res. received check
digit is wrong.
Selected SC factor is invalid for
EAN res. UPC.
Entered digits for EAN res.
UPC are invalid
< 12; > 13.
Selected check digit calculation
is not available in the bar code.
Selected zoom factor is not
available.
Entered sign is not available.
Entered offset value is invalid.
Printhead temperature is too
high.
Defective printhead sensing
device.
With cut an error occurred.
Paper jam.
Entered data do not correspond
to the characters allowed from
the application identifier.
Operating Manual
Dynacode IP Series
Remedy
Check sent data.
Check connection PC - printer.
Check sent data.
Check connection PC - printer.
Check sent data.
Check connection PC - printer.
Check sent data.
Check connection PC - printer.
Change text.
Change font.
Check sent data.
Check connection PC - printer.
Calculate check digit anew.
Check code data.
Check SC factor.
Check number of digits.
Check calculation of check
digit.
Check bar code type.
Check zoom factor.
Check offset value.
Check offset value.
Reduce contrast.
Change printhead.
Check label run.
Check cutter run.
Check code data.
08.16
Need help?
Do you have a question about the Dynacode IP Series and is the answer not in the manual?