Adjustment Of Pressure Power - Carl Valentin Dynacode IP Series Operating Manual

Thermal transfer coder
Table of Contents

Advertisement

Dynacode IP Series
Pressure power in dependence
of air pressure c53 / i53
(one pressure cylinder)
5
4
3
2
1
0
2
3
4
5
Air pressure in bar
Lift 1 mm
Lift 2 mm
08.16

8.4 Adjustment of Pressure Power

Pressure power in dependence
of air pressure c107 / i107
(two pressure cylinder)
8
7
6
5
4
3
2
1
0
2
3
Air pressure in bar
Lift 3 mm
Lift 1 mm
The pressure power of the printhead can be set with the pressure
regulator. The values are indicated in the following table:
NOTICE!
If the pressure power is set too low then the printhead has no
more contact to the counter-pressure plate. This damages the
printhead due to the missing heat dissipation during the
printout. In case of too low pressure an error message
appears. This error message is to protect the printhead for
overheating only and is not to use as print quality control (the
control suffers with too low pressure, too).
The Lift indicates the distance between printhead and counter-
pressure plate in idle mode of the device.
Recommended pressure
power:
Max. pressure power:
Recommended pressure power:
Max. pressure power:
As the mechanical wear and tear of the printhead increases with the
pressure power, the pressure power should be as low as possible.
Operating Manual
Installation and Initial Operation
4
5
Lift 2 mm
Lift 3 mm
Dynacode 53
40 N
45 N
40 N
45 N
Pressure power in dependence
of air pressure c128 / i128
(two pressure cylinders)
8
7
6
5
4
3
2
1
0
2
3
4
5
Air pressure in bar
Lift 1 mm
Lift 2 mm
Lift 3 mm
Dynacode 107 Dynacode 128
40 N
40 N
45 N
45 N
33