Provision the RPR Line Module
Once the RT GigE SM is provisioned, the following features of the RPR Line Module must be
set:
• Provision the Timing
• Provision the Hub/Spoke
• Provision IGMP Multicast VLAN
Provision the Timing
The active RPR Line Module must be provisioned with LoopA being West and LoopB being
East. To provision the RPR timing, complete the following:
1. From the RPR Line Module menu, select Provisioning , and press E
2. From the Provisioning menu, select Timing , and press E
3. From the Timing Configuration menu, press E .
4. From the Timing Configuration menu, select Set Timing to Loop B, and press E
5. From the Timing Configuration menu, press W .
6. From the Timing Configuration menu, select Set Timing to Loop A, and press E
Provision the Hub/Spoke
Rings originating at a COT Node require no provisioning.
NOTE
• If an RPR ring originates at a Remote Terminal, then the Hub/Spoke Mode
must be set to Hub on the originating Node.
• The COT Node automatically sets to Hub Mode.
65K510DEP08-1A
Appendix L, RPR Provisioning - Remote Terminal (RT) Provisioning
NTER
.
NTER
.
NTER
.
.
NTER