Provision The Rpr Line Module; Provision The Timing; Provision The Hub/Spoke - ADTRAN Total Access 5000 Deployment Manual

Hide thumbs Also See for Total Access 5000:
Table of Contents

Advertisement

Provision the RPR Line Module

Once the RT GigE SM is provisioned, the following features of the RPR Line Module must be 
set:
• Provision the Timing
• Provision the Hub/Spoke
• Provision IGMP Multicast VLAN

Provision the Timing

The active RPR Line Module must be provisioned with LoopA being West and LoopB being 
East. To provision the RPR timing, complete the following:
1. From the RPR Line Module menu, select  Provisioning , and press  E
2. From the Provisioning menu, select  Timing , and press  E
3. From the Timing Configuration menu, press  E .
4. From the Timing Configuration menu, select Set Timing to Loop B, and press  E
5. From the Timing Configuration menu, press  W .
6. From the Timing Configuration menu, select Set Timing to Loop A, and press  E

Provision the Hub/Spoke

Rings originating at a COT Node require no provisioning.
NOTE
•  If an RPR ring originates at a Remote Terminal, then the Hub/Spoke Mode
must be set to Hub on the originating Node.
•  The COT Node automatically sets to Hub Mode.
65K510DEP08-1A
Appendix L, RPR Provisioning - Remote Terminal (RT) Provisioning
NTER
.
NTER
.
NTER
.
.
NTER
L-9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ta 5000

Table of Contents