Central Office Terminal (COT) Node Provisioning
The COT Node is provisioned by setting the provisioning on the RPR Line Module.
NOTE
The GigE SM in the COT Node requires no provisioning for the timing source
or the Hop Count.
Provision the RPR Line Module
This subsection details the following information:
• RPR Line Module Provisioning Defaults
• Access the RPR Line Module
• Provision the RPR Line Module Service State
• Provision the Hub/Spoke
• Provision the Timing
• Provision IGMP Multicast VLAN
RPR Line Module Provisioning Defaults
When the RPR Line Module is installed in a Total Access 5000 shelf, the SCM queries the
system (local and clustered shelves) to synchronize its database. No user intervention is
required for this process. Provisioning is handled without user entry if Auto‐Provisioning is
enabled. Otherwise, provisioning must be accomplished manually through the SCM menu
system.
Table L‐2 shows the minimum list of factory defaults and values that are loaded after instal‐
lation and self‐test. These defaults and values provide the minimum configuration for turn up
of the RPR Line Module.
Provisioning Option
Card Service State
Card Service State
Redundancy
Revertive
Revertive Timeout
RPR Provisioning
Keepalive Timeout (ms)
65K510DEP08-1A
Appendix L, RPR Provisioning - Central Office Terminal (COT) Node Provisioning
Table L-2. Default Provisioning Options
Available Options
IS (In Service);
OOS‐UAS (Out of Service ‐ Unas‐
signed);
OOS‐MA (Out of Service ‐ Mainte‐
nance)
Revertive;
Non Revertive
15–65535 seconds
2–200 milliseconds
Default Setting
OOS‐MA
Non Revertive (dis‐
able)
15 s
5 ms
L-3