ADTRAN Total Access 5000 Deployment Manual page 77

Hide thumbs Also See for Total Access 5000:
Table of Contents

Advertisement

!
WARNING
Installing fuses in the fuse and alarm panel at this stage will provide power to
the NetVanta 800. There will be power to pins and connectors on the rear
panel and inside the NetVanta 800. Exercise caution to avoid electrical shock.
5. If the customer site is equipped with local alarm capability, connect the CRIT (critical), 
65K510DEP08-1A
a. Install appropriate fuses in the slots in the fuse and alarm panel that serves the 
NetVanta 800.
b. Using a voltmeter, verify that the operating voltage is within the specifications for A 
or B power feeds. For more information, refer to Specifications on the back.
c. Remove the fuses from the A and B slots for the pair.
MAJOR
, and  MINOR  alarm leads from the on‐site alarm equipment to the Common ( C ), 
Normally Open ( NO ), or Normally Closed ( NC ) wire‐wrap terminals on the NetVanta 800 
rear panel.
These connections will enable audible and/or visual indicators from the on‐site alarm 
equipment.
Section 2, Installation - Install the NetVanta 800/80000
2-29