Provision the Node Number and Network Name
The default Total Access 5000 Node number is 0. When the Node number is 0, the SCM does
not recognize any other modules in the shelf.
To set the Node number, complete the following procedure:
1. From the Enable prompt, type configure terminal , and press E
!
CAUTION
The factory default setting for Network is Node 0. For single‐node
applications (EoCu, EoTDM, BSM, etc.), the node number is set to 1.
2. From the Global Configuration prompt, set the node number by typing node-number
3. From the Global Configuration prompt, set the network name by typing network-name
NOTICE
The Network Name must not duplicate the TID/chassis‐id. If using Total
Access EMS the Network Name must be a unique name for node discovery.
4. Type end , and press E
65K510DEP08-1A
Section 3, Common Provisioning - Provision the Node Number and Network Name
bal Configuration prompt.
, and press E
<1-64>
NTER
, and press E
WORD
NTER
.
NTER
.
to return to the Enable prompt.
NTER
to access the Glo‐
3-5