Ncte B Configuration; Ncte Ethernet Oam Example Using Component 2; Ncte A Configuration - ADTRAN Total Access 5000 Deployment Manual

Hide thumbs Also See for Total Access 5000:
Table of Contents

Advertisement

NCTE B Configuration

NCTE Ethernet OAM Example Using Component 2

In the following example, the user is creating a level 6 MD in the customer network which is 
encapsulated by an s‐tag and is transparent across the provider network.  Up MEPs will 
transmit/receive CFM messages with the c‐tag defined by Component 2 of the Maintenance 
Association. Due to the rules of the EVC and EVC‐map, these messages will have the s‐tag 
stacked before egressing the MEN‐port. For the Up MEPs to become active, the EVC‐map 
matching on CE‐VLAN‐ID 200 must be in the Running state.  The MA has two endpoints 
(NCTE A and NCTE B). The user is creating a single MA with VLAN 200. NCTE A has a MEP 
with a MEPID of 600 and NCTE B has a MEP with a MEPID of 601.  The CCM interval is not 
explicitly configured so the default CCM interval of 1‐second will be used.

NCTE A Configuration

65K510DEP08-1A
Appendix C, Ethernet OAM Provisioning - Ethernet OAM on the NetVanta 800/8000 Series NCTE
component 1 vlan 1010
exit
exit
exit
interface efm-group 1
ethernet cfm mep 2000 MD_5 MA_1010 down
ccm-enabled
no shutdown
exit
ethernet cfm
ethernet cfm domain char-string MD_5 level 5
association char-string MA_1010
remote-mep 2000
component 1 vlan 1010
exit
exit
exit
interface efm-group 1
ethernet cfm mep 2001 MD_5 MA_1010 down
ccm-enabled
no shutdown
exit
evc evc1010
s-tag 1010
connect men-port efm-group 1/0/1
no shutdown