Mitsubishi melservo-j2 series Instruction Manual page 86

Built-in positioning function servo amplifier
Hide thumbs Also See for melservo-j2 series:
Table of Contents

Advertisement

4. OPERATION
Servo motor
speed
Point table
selection
Start signal
(ST1 or ST2)
Rough match
(CPO)
In position
(INP)
Point Table No.
n
n
1
n
2
Note: 1. Always set "1" or more.
2. Always set "0" to the auxiliary function of the last point table among the consecutive point tables.
Point table No. n
Point table No. n+1
Dwell
time (an)
No.n
Dwell Time [ms] (Note 1)
an
an
1
Invalid
Point table No. n 2
Dwell
time
(an 1)
Auxiliary Function
1
1
0 (Note 2)
4 - 15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-j2-c

Table of Contents