CONFORMANCE WITH UL/C-UL STANDARD
(1) Servo amplifiers and servo motors used
Use the following models of servo amplifiers and servo motors:
Servo amplifier series: MR-J2-10C to MR-J2-350C
Servo motor series
(2) Installation
Install a fan of 100CFM air flow 10.16 cm (4 in) above the servo amplifier or provide cooling of at least
equivalent capability.
(3) Short circuit rating
Having been subjected to UL tests in the alternating-current circuit whose peak current is limited to
5000A or less, this servo amplifier conforms to this circuit.
(4) Capacitor discharge time
The capacitor discharge time is as listed below. To ensure safety, do not touch the charging section for
10 minutes after power-off.
Servo Amplifier
MR-J2-10C • 20C
MR-J2-40C • 60C
MR-J2-70C to 350C
(5) Options and auxiliary equipment
Use products which conform to the UL/C-UL Standard.
About the Manuals
This Servo Amplifier Instruction Manual and the MELSERVO Servo Motor Instruction Manual are
required if you use the MELSERVO-J2-C for the first time. Always purchase them and use the
MELSERVO-J2-C safely.
Relevant Manual
MELSERVO-J2-C Installation Guide
MELSERVO Servo Motor Instruction Manual
EMC INSTALLATION GUIDELINES
: HC-KF
-UE
HC-MF
-UE
HC-SF
HC-RF
HC-UF
Discharge Time [min]
1
2
3
Manual Name
Manual No.
IB(NA)67367
SH(NA)3181
IB(NA)67310
A - 9