Mitsubishi melservo-j2 series Instruction Manual page 119

Built-in positioning function servo amplifier
Hide thumbs Also See for melservo-j2 series:
Table of Contents

Advertisement

5. PARAMETERS
Class No. Symbol
44
ZTM
Stopper type zeroing stopper time
In stopper type zeroing, used to set the time from when the machine
part is pressed against the stopper and the torque limit set in
parameter No.45 (ZTT) is reached to when the home position is set.
45
ZTT
Stopper type zeroing torque limit
Used to set the torque limit value relative to the max. torque in [%]
in stopper type zeroing.
46
LMP Software limit
47
Used to set the address increment side software stroke limit. The
software limit is made invalid if this value is the same as in
"software limit
Set the same sign to parameters No.46 and 47. Setting of different
signs will result in a parameter error.
48
LMN Software limit
49
Used to set the address decrement side software stroke limit. The
software limit is made invalid if this value is the same as in
"software limit ".
Set the same sign to parameters No.48 and 49. Setting of different
signs will result in a parameter error.
50
LPP Position range output address
51
Used to set the address increment side position range output
address. Set the same sign to parameters No.50 and 51. Setting of
different signs will result in a parameter error.
52
LNP Position range output address
53
Used to set the address decrement side position range output
address. Set the same sign to parameters No.52 and 53. Setting of
different signs will result in a parameter error.
54
For manufacturer setting
to
Must not be changed.
66
Name and Function
".
Set address:""""""
Lower 3
Upper 3
digits
digits
Set address: """"""
Lower 3
Upper 3
digits
digits
Set address:""""""
Upper 3
Lower 3
digits
digits
Set address:""""""
Upper 3
Lower 3
digits
digits
Parameter No. 47
Parameter No. 46
Parameter No. 49
Parameter No. 48
Parameter No. 51
Parameter No. 50
Parameter No. 53
Parameter No. 52
5 - 12
Initial
Setting
Unit
Value
Range
100
ms
5 to 1000
15
%
1 to 100
0
10
999999
STM
m
to
999999
0
10
999999
STM
m
to
999999
0
10
999999
STM
m
to
999999
0
10
999999
STM
m
to
999999
Refer To
Section
4.4.5
Section
4.4.5
Section
5.2.8
Section
5.2.8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-j2-c