Main Ac Blower; Reflectors (Including Heat Dump) - Christie D4K25 Service Manual

Hide thumbs Also See for D4K25:
Table of Contents

Advertisement

5.12.7 Main AC Blower

(Estimated Replacement Time: 60 minutes + 10 minute LampLOC™ Alignment)
The Main AC Blower or Lamp Blower is located at the rear of the
projector directly behind the lamp.
1. Remove lamp door. See
2. Remove lamp. See
3. Remove the projector's rear lid. See
5-10.
4. Disconnect the main AC blower power harness.
5. Using a 3mm hex key, remove the four screws securing the
blower to its mounting bracket (Figure 5-49).
6. Carefully, remove the fan out the top of the projector.
7. When installing, repeat instructions in reverse. Perform
LiteLOC
.

5.12.8 Reflectors (Including Heat Dump)

(Estimated Replacement Time: 90 minutes + 10 minute LampLOC™ Alignment)
1. Remove lamp door. See
page
5-8.
2. Remove lamp. See
30.
3. Remove rear lid.
4. Remove the four hex screws securing the
reflector casting to the baseplate.
5. Remove the lamp anode yoke assembly. See
5.12.1 Anode Yoke, on page
6. Lift the casting up slightly to clear the
alignment pins, then tilt the top of the casting
forward and down.
7. Remove the entire reflector assembly out the
open lamp door.
8. Using a 3mm hex key, remove the four screws
securing the reflector cover (also called the heat dump).
9. Remove four pressure clips to remove the front and rear reflectors (Figure 5-50).
When installing, repeat instruction in reverse. Perform LampLOC
Lamp Position (LampLOC™), on page
D4K25 Service Manual
020-100880-01 Rev. 1 (06-2012)
5.4.7 Lamp Door, on page 5-8.
5.12.5 Lamp, on page 5-30.
5.4.11 Rear Lid, on page
5.4.7 Lamp Door, on
5.12.5 Lamp, on page 5-
5-27.
3-3.
Section 5: Parts and Module Replacement
Figure 5-49 Main AC Blower
Figure 5-50 Rear Reflector
alignment. For details, see
3.3 Adjusting
5-35