Christie D4K25 Service Manual page 103

Hide thumbs Also See for D4K25:
Table of Contents

Advertisement

LAMP INTENSITY CALIBRATION (LCA) (Continued)
MAXS
MINF
MINS
NONE
EXAMPLES:
(LCA+MINF 10) Set 10 footlamberts as measured brightness at minimum lamp power
(LCA+MINF?) Get footlamberts on minimum lamp power
(LCA+MINS 5000) Set 5000 as reading value from the light sensor at minimum lamp power
(LCA+MAXF 17) Set 17 footlamberts as measured brightness as maximum lamp power
(LCA+MAXF?) Get footlamberts at maximum lamp power
(LCA+MAXS 15000) Set 15000 as reading value from the light sensor on maximum lamp power
LUT CLUT CONTROL (LCT)
Set Look up Table (LUT) Color Look Up Table (CLUT) file for the specified channel. The CLUT is used during
color processing in the electronics.
SUBCODE
Cxxx
NONE
EXAMPLES:
(LCT+C108 "9x9x9") Use PCF file "9x9x9" on channel 108
(LCT+C108?) Get LUT-CLUT file name on channel 108
(LCT?L) List all entries of LUT-CLUT control
LAMP INTENSITY CALIBRATION (LEN)
Define model and serial number for primary installed lens and auxiliary lens.
SUBCODE
AMOD
ASER
MMOD
MSER
NONE
EXAMPLES:
(LEN+MMOD?L) List supported lens model
(LEN+AMOD?L) List supported auxiliary lens model
(LEN+MMOD 1 Set lens model
(LEN+MSER "xxxx") Set lens serial number
D4K25 Service Manual
020-100880-01 Rev. 1 (06-2012)
Set sensor value at maximum lamp power
Set footlamberts at minimum lamp power, the value should be (footlamberts * 100)
Set sensor value at minimum lamp power
Not available
DESCRIPTION OF USE
Replace xxx with the channel number. Valid range is 101 - 164.
Select CUT for the current channel.
DESCRIPTION OF USE
Auxiliary lens model
Auxiliary lens serial number
Main lens model
Main lens serial number
Not available
Section 7: Serial API
7-9