2.3

AC/Power Precautions

Installation of this projector requires that an electrician hard-wire (permanent-wire) a single-phase feed from
the projector to the AC supply at the building site. Operate the projector at the specified voltage.
• This product may be connected with multiple power sources. Before opening, removal all
hazardous voltages by disconnecting all power sources.
• DO NOT attempt operation if the AC supply is not within the specified voltage range.
• This product does not include a built in AC breaker. A 30-32A double pole, UL listed wall cir-
cuit breaker is required. It must be part of the building installation and easily accessible.
• DO NOT use a wall breaker greater than 32A. This could result in severe damage to the pro-
jector in the event of a failure.
• Protection from over-currents, short circuits and earth faults must be part of the building
installation. A disconnect device (double pole switch or circuit breaker with minimum 3 mm
contact gap) must be readily accessible within the projection room.
• Disconnect projector from AC before opening any enclosure.
• DO NOT allow anything to rest on the power cord. Locate the projector where the cord can-
not be abused by persons walking on it or objects rolling over it. Never operate the projec-
tor if the power cable appears damaged in any way.
• DO NOT overload power outlets and extension cords as this can result in fire or shock haz-
ards.
• Note that only Christie authorized service technicians are permitted to open any enclosure
on the product and only if the AC has been fully disconnected from the product.
D4K25 Service Manual
020-100880-01 Rev. 1 (06-2012)
Section 2: Service Guidelines
2-3

Advertisement

Table of Contents
loading