FOCUS LENS POSITION ADJUSTMENT (FCS) (Continued)
STOP
MOVR
EXAMPLES:
(FCS 500 1) Move lens to position 500 at focus motor with positive approach
(FCS 500 -1) Move lens to position 500 at focus motor with negative approach
(FCS+C101 -500 1) Set lens focus position for channel 1 to -500 with positive approach
(FCS?) Return current motor position
(FCS+CALB 1) Calibrate the focus axis
(FCS+RSET 1) Reset the focus axis
(FCS+STRT 1) Starts motor moving in positive direction
(FCS+STOP) Stops motor
(FCS+MOVR -100) Move motor 100 steps in negative direction
(FCS+MOVR 200) Move motor 200 steps in positive direction
GAMMA CONTROL (GAM)
Gamma control, gamma file will be set when PCF in Use (PIU) is off. This control describes the gamma response
curve for the source signal.
SUBCODE
Cxxx
NONE
EXAMPLES:
(GAM+C108 "gamma 2.6") Use file "gamma 2.6" on channel 108
(GAM+C108?) Get gamma file name on channel 108
(GAM?L) List all entries of gamma control
LAMP HISTORY (HIS)
Retrieve the history of installed lamp entries, including the current lamp. There is an individual entry for each lamp
in the history. The format for each entry is: (HIS!AAA "BBBB/BB/BB" "C" "D" EEE FFF GGG HHH III JJJ
KKK).
A = Lamp Number
B = Date Installed
C = Serial Number
D = Type
E = Strikes
F = Failed Strikes
G = Failed Restrikes
H = Unexpected Lamp Off
I = Pre-installed Hours (will always return "00000")
J = Lamp Hours
K = Lamp Rotation
D4K25 Service Manual
020-100880-01 Rev. 1 (06-2012)
Stops the motor. Write-only for v1.3 or newer.
Moves the motor a given number of steps based on the current location. Write-only for v1.3 or newer.
DESCRIPTION OF USE
Replace xxx with the channel number. Valid range is 101 - 164.
Select gamma for the current channel.
Section 7: Serial API
7-5

Advertisement