5.4.11 Rear Lid

(Estimated Replacement Time: 15 minutes)
1. Remove external ducting.
2. Remove the front top lid. See
Lid, on page 5-5.
3. Using a #2 Phillips
screws securing the Rear Lid to the chassis
(Figure 5-10).
4. Open the lamp door (Figure 5-6).
5. Remove the LVPS/LPS cover (Figure 5-7).
6. Lift the rear lid up and remove.
5.5

Air Filters

5.5.1 Light Engine Air Filter

NOTICE: DO NOT try to clean and reuse old filters. The air filters used in this product cannot be cleaned
thoroughly enough for reuse. Reusing filters can lead to the contamination of optical components.
(Estimated Replacement Time: 4 minutes)
The main air filter of the projector is located on the
operator's side of the projector near the front. It is
responsible for cleaning the intake air into the light
engine compartment. It is strongly recommended this
filter be replaced whenever a lamp is replaced or sooner
in dusty and/or dirty environments. No tools required.
1. Push down on the two snap tabs at the top of the
cover (See Figure 5-8).
2. Lift the cover up enough for the bottom tabs to clear
the frame and remove.
3. Slide the air filter out from behind the air filter
cover and discard (Figure 5-11).
4. When replacing, insert a new air filter with the
airflow indicator pointing into the projector. This
will ensure contaminants are not forced into the
projector.
5-10
5.4.2 Front Top
, remove the two captive
Figure 5-10 Rear Lid
Figure 5-11 Light Engine Air Filter Cover
D4K25 Service Manual
020-100880-01 Rev. 1 (06-2012)

Advertisement