ILS FILE (ILF) (Continued)
NONE
SAVE
FDEL
EXAMPLES:
(ILF+C101 "ILS Flat") Set ILS file for channel 1 to file "ILS Flat"
(ILF?L) List all available ILS files
(ILF 1) Set ILS file for current channel to index 1 in file list
(ILF+Save "filename") Save the active ILS values to a file named "filename". If the file doesn't exist, it will be created. If the
file already exits, it will be overwritten.
(ILF+FDEL "LensSetup1") Delete the "LensSetup1" ILS file from the system.
(ILF+FDEL 3) Delete the ILS file at index 3 in the list.
INTELLIGENT LIGHT SYSTEM CONFIG (ILS)
Enable/disable the Intelligent Lens System for each channel.
SUBCODE
ACLB
CALB
CSTS
INST
NONE
RSET
RSTS
EXAMPLES:
(ILS 1) Enable ILS, lens will be moved to the position in each channel
(ILS 0) Disable ILS, position data in each channel will not be used. Moving lens will not affect any channel setting
(ILS+CALB 5) Calibrate all axes of the lens. Set only command
(ILS+RSET 5) Reset all axes of the lens
(ILS+ACLB 1) Reset lens automatically when power on
D4K25 Service Manual
020-100880-01 Rev. 1 (06-2012)
Select the ILS file for a current channel.
Save the currently active ILS data to a file. Will overwrite an existing file with the same name. Requires
advanced access level.
Delete an ILS File
DESCRIPTION OF USE
Enable/disable the Auto Lens Mount and Lens reset feature. Once ACLB is turned on, lens
mount and lens system will be reset automatically when system is powered on.
Calibrate travel range and backlash on specified. Only valid parameter for this command is 5.
SET only command.
Motor calibration status (0-100%)
Sets ILS to installed
Enable/Disable the Intelligent Lens System for each channel. (1/0)
Move motor to center flag and then move back to current position. Only valid parameter for this
command is 5. SET only command.
Motor reset status (0-100%)