LAMPLOC™ MODULE (LLM)
Allows adjustment of lamp position to optimize intensity and uniformity of the optical system. This is referred to
as the LampLOC™ feature and can be done automatically or manually.
SUBCODE
AUTO
CALI
MTRX
MTRY
MTRZ
NONE
STAT
EXAMPLES:
(LLM+MTRX 100) Move motor X to position 100
(LLM+AUTO 1) Do LampLOC™ automatically
(LLM+AUTO 0) Abort LampLOC™. It will restore the motors to previous position automatically
(LLM+AUTO?) Get running status. (LLM+AUTO!000) indicates finished, (LLM+AUTO!001) indicates running
(LLM+STAT ?) Get the progress feedback of the Auto mode (0-100%)
ADJUST ALL LENS POSITION PARAMETERS SIMULTANEOUSLY (LMV)
Adjust all lens position parameters simultaneously.
SUBCODE
NONE
EXAMPLES:
(LMV 1000 1500 500 -500 -1 -1 1 1)
LOCAL SETTINGS (LOC)
et the time format and display options for temperature units.
S
SUBCODE
LANG
D4K25 Service Manual
020-100880-01 Rev. 1 (06-2012)
DESCRIPTION OF USE
Set to 1 to do LampLOC™ automatically. It will do calibration first, then move the X, Y, Z-
motors to find the maximum brightness. Set to 0 to cancel auto adjustment and restore the pre-
vious position. Reset to 0 when it has finished.
Calibrate LampLOC motors.
Moving X-axis motor manually. Data range from ±250.
Moving Y-axis motor manually. Data range from ±250.
Moving Z-axis motor manually. Data range from ±175.
Not Available
Provides feedback (status) on the progress of the Auto mode. Read-only command. Data range
from 0 to 100, where 100 indicates the LampLOC™ is finished.
DESCRIPTION OF USE
(LMV <lho><lvo><zom><fcs><lhodir><lvodir><zomdir><fcsdir>)
<lhodir>, <lvodir>, <zomdir>, and <fcsdir> represent the horizontal, vertical, zoom, and
where
focus position information. Valid values for direction are 1 and -1.