7 Serial API
This section provides a list of serial API commands that you can run to modify projector settings.
7.1

Function Codes

AUTOMATIC SCAN TYPE DETECTION (ASD)
Set the Automatic Scan Type Detection ON or OFF for the current channel.
SUBCODE
Cxxx
NONE
EXAMPLES:
Get the current status of Automatic Scan Type Detection on the current active channel.
(ASD?)
(ASD+C108?) Get the current status of Automatic Scan Type Detection on the provided channel.
(ASD+C108 1) Use Automatic Scan Type Detection on channel 108.
(ASD+C108 0) Do not use Automatic Scan Type Detection on channel 108.
BAUD RATE (BDR)
Set the baud rate for a serial communications port.
SUBCODE
PRTA
EXAMPLES:
(BDR+PRTA6) Set baud rate on port A to 115200 bits per second
(BDR+PRTA?) Get baud rate (BDR+PRTA!006 "115200)
CHANNEL (CHA)
Select Channel configuration to use. Channel range is 101 to 164. Channel configuration sets the input routing and image pro-
cessing options for input signals.
SUBCODE
NONE
EXAMPLES:
(CHA?) Get current active channel
(CHA 108) Set channel 108 as active channel
D4K25 Service Manual
020-100880-01 Rev. 1 (06-2012)
DESCRIPTION OF USE
Replace xxx with channel number. Valid range is 101 - 164.
Select use Automatic Scan Type Detection for the current channel.
DESCRIPTION OF USE
Set the baud rate on port A. Rates can be 1200, 2400, 9600, 19200, 38400, 57600, or 115200.
DESCRIPTION OF USE
Select Channel. Valid range 101 - 164