PAT700 Total Organic Carbon Analyzer – Specifications
Appendix A: Specifications
PAT700 specifications are subject to change without notice.
TOC specifications
Operating range
Display resolution
Accuracy
Repeatability
Limit of detection
Conductivity and resistivity specifications
Conductivity range (TOC)
Conductivity display resolution
Conductivity accuracy
Resistivity range
Resistivity display resolution
Available resistivity modes
Temperature specifications
Ambient operating range
Display resolution
Measurement accuracy
Sample water range
Anatel
0.5 to 2,000 ppb as carbon
0.1 ppb
±1 ppb or 5%, whichever is greater
±0.3 ppb or ±1%, whichever is greater
0.5 ppb
0.05 to 150 µS/cm (@ 25 °C)
0.01 µS/cm
±1% over full range (uncompensated)
Ω
0.2 to 18 M
-cm (@25 °C)
0.01 over full range
Temperature compensated to 25 °C, or uncompensated
10 to 40° C (50 to 104 °F)
0.1 over full range
±0.4°C
5 to 95 °C (41 to 203 °F)