Agilent Technologies 8163A User Manual page 207

Lightwave multimeter,lightwave measurement system,lightwave multichannel system
Hide thumbs Also See for 8163A:
Table of Contents

Advertisement

How to Use an Optical Switch module
Screen Elements
Configuration
Agilent 8163A/B, 8164A/B, and 8166A/B User's Guide, Fourth Edition
Figure 129
Optical Switch module, 8164A/B User Interface Details
All the figures in this chapter are taken from an 8164A/B mainframe.
The user interface for an 8163A, 8163B, 8166A or 8163B mainframe
may differ in detail but the available functionality is identical.
The Optical Switch configuration is indicated at the top left of the user
interface.
In Figure 129, 2x2 indicates that this is an Agilent 81594A/S 2x2 non-
blocking (crossover) switch.
Route
The [Route A <->] field describes the route between port A and another
numbered port within the Optical Switch module.
If present, the [Route B <->] field describes the route between port B
and another numbered port within the Optical Switch module.
In Figure 129:
– The [Route A <->] field shows that, within the Optical Switch
module, port A is connected to port 1.
– The [Route B <->] field shows that, within the Optical Switch
module, port B is connected to port 2.
N O T E
For all switch modules the signal paths are bi-directional.
Switching Optical Routes
207

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

8166a8166b8163b8164a8164b

Table of Contents