How To Save And Recall - Owon MSO5022 User Manual

Portable mixed signal digital storage oscilloscope
Table of Contents

Advertisement

User's Manual of OWON Color Mixed Signal Digital Storage Oscilloscope

How to save and recall

Use the storage menu to save or recall waveforms and setting. The storage
depth of waveform for sampling storage is normal (256K) and low storage (16K).
And it can divide into 4 groups. Memory setting includes current sampling setting,
BUS setup, display setting, threshold setting and trigger setting. And possible to
save 10 groups of settings. Waveform storage and setting storage menu as Fig.
81.
Storage menu instruction as below:
Function
Setting
Memory
Waveform
SEL
Setups
Memory
Waveform0
ID
Waveform3
Setups
Setups 9
Save
Recall
For example, to set "WAVE 0" in memory ID to save current waveform and
"setting 0" to save current setting. Follow up below steps:
1. Press "C(SAVE/REL)" after data acquisition finished and storage menu
appears
2. Press "F1" till storage display as "waveform"
3. Press "F2" till memory ID. display as "waveform 0"
4. Press "F3" to save current display waveform. Info window will show
"waveform saving" then show as "waveform saved successfully"
when storage finished.
Fig 81:Storage menu
Instruction
Waveform for storage or recall
Setups for storage or recall
Storage 4 groups of waveform
0
Storage 10 groups of setups
Save current waveform/setting in designated
No.
Recall waveform/ setups in designated No.
82