■ When setup method selection button = SPECIFIED IP ADDRESS
If you're using DANTE-ACCEL, use the SPECIFIED IP ADDRESS field to specify the IP address of the
PC. Since the IP address of DANTE-ACCEL will differ from the IP address used by CL Extension, you
must specify the IP address manually.
1
This screen contains the following items.
1
IP ADDRESS knobs
Use the multifunction knobs to specify the IP address.
NOTE
• As the IP address, specify the IP address of the PC that is running Nuendo Live.
• Set the address of that PC in the range of 169.254.0.0 – 169.254.255.255, and set the subnet
mask as 255.255.0.0.
• For the PC in which DANTE-ACCEL is installed, the Dante port of DANTE-ACCEL as well as the
Ethernet port of the PC must both be connected to the same network.
Refer to the illustration below.
PC
Ethernet
DANTE-ACCEL
P
S
CL
Dante
P
S
SW
(Primary)
SW
(Secondary)
NOTE
Depending on the firmware version, DANTE-ACCEL might not support redundant networking.
Refer to the following website to check whether your version of the DANTE-ACCEL (Dante
Accelerator) firmware supports redundant networking.
http://www.yamahaproaudio.com/
2.
When you have finished making settings, press the OK button to close the
NUENDO LIVE SET UP popup window.
191
Recorder