Using Gpi (General Purpose Interface) - Yamaha CL1 Reference Manual

Hide thumbs Also See for CL1:
Table of Contents

Advertisement

2.
Press a HA device select button to access the REMOTE HA SELECT popup window.
1
3
This screen contains the following items.
1
DEVICE LIST
Shows a list of the HA devices on the Dante audio network.
2
with RECALL button
If this button is on, the settings saved in the CL series console will be applied to the HA device
when the CL series console starts up and when a scene is recalled.
3
DEVICE LIST select knob
Use the multi-function knob to select the HA device that you want to mount.
NOTE
• Do not specify "with RECALL" if an HA device is shared by multiple CL series consoles and
settings have already been made on a different CL series console.
• The HA device can also be operated from a CL series console that is not set to "with RECALL."
3.
After you've selected the HA device to mount, press the OK button to close the
REMOTE HA SELECT popup window.
If you've changed the setting by pressing the "with RECALL" button, a confirmation dialog box
will appear.
To make the setting, press the OK button.

Using GPI (General Purpose Interface)

The rear panel GPI (General Purpose Interface) connector can be used as an input/output connector.
This connector provides five GPI IN ports and five GPI OUT ports. For example you can use an
external switch to control internal parameters of the CL series console or to switch scenes. Conversely,
operations or scene changes performed on the CL series console can send control signals to an external
device.
For details on how to send control signals to an external device when you switch scenes, refer to
"Outputting a control signal to an external device in tandem with scene recall (GPI
2
Using GPI IN
You can use the GPI IN ports of the GPI connector to control the parameters of the CL series console
from an external device. For example, you could use an external switch to turn the CL series console's
Talkback on/off, operate the Tap Tempo function, or switch scenes.
1.
Connect an external device to the CL series console's GPI connector.
2.
In the function access area, press the SETUP button to access the SETUP screen.