11.10

PROFIdrive status word

Table 11.6 gives the description of each bit in the PROFIdrive status word.
Table 11.6 PROFIdrive status word bit functions
Bit
Value
1
0
0
1
1
0
1
2
0
1
3
0
1
4
0
1
5
0
1
6
0
1
7
0
1
8
0
1
9
0
1
10
0
11-15
0
SM-PROFIBUS DP-V1 User Guide
Issue : a
Function
Comments
Ready to switch on
Power supply switched on, the drive is inhibited.
Not ready to switch
Power supply switched off.
on
Ready To Operate
Drive is ready to run.
Not Ready To
Drive is not ready to run.
Operate
Operation Enabled
Drive is operational.
Operation Disabled
Drive is not operational.
Drive faulted, and thus not operational, goes into the
Fault Present
switch-on inhibit status after acknowledgment and the fault
has been removed. Fault number in the fault parameter.
No Fault Present
Drive Healthy
Coast Stop Not
Coast Stop command is not active.
Activated
Coast Stop Activated Coast Stop command is active.
Quick Stop Not
Quick Stop command is not active.
Activated
Quick Stop Activated Quick Stop command is active.
Switch-on Inhibited
Power supply switched on, the drive is inhibited.
Switch-on Not
Power supply switched on,
Inhibited
Warning Present
Not Implemented
No Warning Present Not Implemented
Speed Error Within
'At Speed' (Pr 10.06) = 1
Tolerance
Speed Error Out Of
'At Speed' (Pr 10.06) = 0
Tolerance
Control Requested
The automation system is requested to accept control.
No Control
Control only possible on the device itself.
Requested
Speed Or Frequency
'At Speed' (Pr 10.06) = 1 or
Reached/Exceeded
'Above Set Speed' (Pr 10.07) = 1
Speed Or Frequency
'At Speed' (Pr 10.06) = 0 and
Not Reached
'Above Set Speed' (Pr 10.07) = 0
Reserved