Diagnostics

This section provides basic diagnostic information intended to enable resolution of the
most common problems encountered when setting up a SM-PROFIBUS DP-V1 on a
PROFIBUS-DP network.
A high percentage of problems reported are basic set-up problems that can be avoided
by using the information in this chapter. Start by using the Diagnostic flow chart on
page 60 to determine the possible cause of a problem. If after following the flow chart
you are still experiencing problems please contact your supplier or LEROY-SOMER for
support.
Please note that support will be limited to the setting up and networking of the drive.
NOTE
10.1

Module ID code

Table 10.1
Pr MM.01
The module ID code indicates the type of module fitted in to the slot corresponding to
menu MM. The module ID code for SM-PROFIBUS DP-V1 is 403.
10.2

Module firmware version

Table 10.2 SM-PROFIBUS DP-V1
Pr MM.02
Table 10.3 SM-PROFIBUS DP-V1
Pr MM.51
Unidrive SP (Sizes 1 to 6) / Unidrive SPM / Mentor MP
The software version of the Solutions Modules can be identified by looking at Pr 15.02
or Pr 16.02 or Pr 17.02 and Pr 15.51 or Pr 16.51 or Pr 17.51.
Menu 15,16 or 17 is Solutions Module slot dependent with menu 17 being the lowest
position nearest the control terminal connections.
The software version takes the form of xx.yy.zz, where Pr 15.02 or Pr 16.02 or Pr 17.02
displays xx.yy and Pr 15.51 or Pr 16.51 or Pr 17.51 displays zz (e.g. for software version
01.01.00 on a module in the middle Solutions Module slot, Pr 16.02 will display 1.01 and
Pr 16.51 will display 0).
Unidrive SP (SPz) / Digitax ST / Unidrive ES / Affinity
The software version of the Solutions Modules can be identified by looking at Pr 15.02
or Pr 16.02 and Pr 15.51 or Pr 16.51.
Menu 15 or 16 is Solutions Module slot dependent with menu 15 (Unidrive SPz and
Digitax ST) or menu 16 (Unidrive ES and Affinity) being the position nearest the control
terminal connections.
SM-PROFIBUS DP-V1 User Guide
Issue : a
Module ID code
Default
Range
Access
Default
Range
Access
Default
Range
Access
www.leroy-somer.com
403 (SM-PROFIBUS DP-V1)
0 to 499
RO
firmware - major version (xx.yy)
N/A
00.00 to 99.99
RO
firmware - minor version (zz)
N/A
0 to 99
RO