Data Format; Operating Status - Leroy-Somer digitax st User Manual

Sm-profibus dp-v1 solutions module for fieldbus communication
Table of Contents

Advertisement

Table 10.6 Network data rate status
Pr MM.04
10.5

Data format

Table 10.7
Pr MM.05
The default data format is four cyclic words, each cyclic data channel is mapped to a
drive parameter.
The maximum number of 16-bit data words that is possible is thirty-two (in and out) with
NOTE
only cyclic data, thirty-one (in and out) with Mode 1 non-cyclic data and twenty-eight (in
and out) with PPO4 word mode.
10.6

Operating status

Table 10.8
Pr MM.06
The operating status of the SM-PROFIBUS DP-V1 can be viewed in the operating
status parameter (Pr MM.06). When the SM-PROFIBUS DP-V1 is communicating
successfully with the PROFIBUS-DP master controller, Pr MM.06 will give an indication
of the number of cyclic data messages that are being processed per second.
SM-PROFIBUS DP-V1 User Guide
Issue : a
-1
0
1
2
3
4
5
6
7
8
9
Data format
Default
Ranges
Access
Operating status
Default
Range
Access
www.leroy-somer.com
bit/s
Auto-detecting
12M
6.0M
3.0M
1.5M
500k
187.5k
93.75k
45.45k
19.2k
9.6k
4
0-32,100-131& 200 to 228
RW
N/A
-3 to 9999
RO
55