Table 8.3 CT Single Word non-cyclic data mapping
Mapping
parameter
Pr MM.10
Pr MM.11
Pr MM.12
Pr MM.13 to
Pr MM.19
Pr MM.20
Pr MM.21
Pr MM.22
Pr MM.23 to
Pr MM.29
If all IN or OUT mapping parameters are being used when the data format change is
NOTE
implemented the last mapping parameter value will be lost.
8.6.2
CT Single Word protocol
All parameter values for the drive must be written as signed 32-bit data values with data
compression off. If data compression is turned on the size of the mapping will depend
on the size of the source or destination parameter
Decimal point information is inserted automatically when the data value is written to the
NOTE
drive and removed when the data value is read. The number of decimal places of the
target parameter must be known. Writing a value of 1234 to a parameter with two decimal
places will produce a value of 12.34 in the target parameter. Similarly, reading a value of
12.34 will return a 32-bit integer value of 1234.
Table 8.4 CT Single Word Bit Positions
b15
READ
b7
SM-PROFIBUS DP-V1 User Guide
Issue : a
Before format change (Pr MM.05 = 4)
Value
Mapping
1040
Pr 10.40, status word
201
Pr 2.01, post ramp speed ref
0
Not mapped
0
Not mapped
642
Pr 6.42, control word
121
Pr 1.21, digital speed ref 1
0
Not mapped
0
Not mapped
b14
b13
b12
ERR
Reserved
32-BIT
b6
b5
www.leroy-somer.com
After format change (Pr MM.05 = 104)
Value
6150
1040
201
0
6150
642
121
0
.
b11
b10
Stamp Number
b4
b3
b2
Data Byte
Mapping
Pr 61.50, CT Single Word
Pr 10.40, status word
Pr 2.01, post ramp speed ref
Not mapped
Pr 61.50, CT Single Word
Pr 6.42, control word
Pr 1.21, digital speed ref 1
Not mapped
b9
b8
b1
b0
33