IBM x3550 M4 Type 7914 Installation And Service Manual page 793

Table of Contents

Advertisement

201-864-003
Standalone Memory Test Aborted
Explanation: No GAS located in OEM1.
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
201-865-000
Standalone Memory Test Aborted
Explanation: No XSECSRAT key in OEM0 structure.
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related Links:
v
IBM Support Website
Latest level of DSA
v
Latest level of BMC/IMM
v
201-864-003 • 201-865-000
Appendix C. DSA diagnostic test results
775

Advertisement

Table of Contents
loading

Table of Contents