IBM x3550 M4 Type 7914 Installation And Service Manual page 419

Table of Contents

Advertisement

80010901-1402ffff
Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted. (CPU2
VR Temp)
Explanation: This message is for the use case when an implementation has detected an Upper Critical sensor going
high has asserted.
May also be shown as 800109011402ffff or 0x800109011402ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0494
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Reduce the ambient temperature.
2.
Ensure the air baffle is installed correctly.
3.
Check the server airflow. Make sure that nothing is blocking the air from coming into or preventing the air from
exiting the server.
80010901-1403ffff
Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted.
(DIMM AB VR Temp)
Explanation: This message is for the use case when an implementation has detected an Upper Critical sensor going
high has asserted.
May also be shown as 800109011403ffff or 0x800109011403ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0494
SNMP Trap ID: 0
Automatically notify Support: No
User response:
Reduce the ambient temperature.
1.
2.
Ensure the air baffle is installed correctly.
3.
Check the server airflow. Make sure that nothing is blocking the air from coming into or preventing the air from
exiting the server.
80010901-1402ffff • 80010901-1403ffff