IBM x3550 M4 Type 7914 Installation And Service Manual page 573

Table of Contents

Advertisement

806f0a0c-2018ffff
An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on
Subsystem [MemoryElementName]. (DIMM 24)
Explanation: This message is for the use case when an implementation has detected an Over Temperature Condition
for Memory that has been Detected.
May also be shown as 806f0a0c2018ffff or 0x806f0a0c2018ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0146
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure that the fans are operating, that there are no obstructions to the airflow, that the air baffles are in
place and correctly installed, and that the server cover is installed and completely closed.
2.
Make sure that ambient temperature is within the specifications.
3.
If a fan has failed, complete the action for a fan failure.
4.
Replace DIMM n. (n = DIMM number)
806f0a13-0301ffff
A Fatal Bus Error has occurred on system [ComputerSystemElementName]. (CPU 1 PECI)
Explanation: This message is for the use case when an implementation has detected a Bus Fatal Error.
May also be shown as 806f0a130301ffff or 0x806f0a130301ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0244
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
Reseat the microprocessor, and then restart the server.
2.
Replace microprocessor n. (n = microprocessor number)
806f0a0c-2018ffff • 806f0a13-0301ffff