IBM x3550 M4 Type 7914 Installation And Service Manual page 534

Table of Contents

Advertisement

806f0607-2584ffff • 806f060d-0400ffff
806f0607-2584ffff
An SM BIOS Uncorrectable CPU complex error for [ProcessorElementName] has asserted. (All
CPUs)
Explanation: This message is for the use case when an SM BIOS Uncorrectable CPU complex error has asserted.
May also be shown as 806f06072584ffff or 0x806f06072584ffff
Severity: Error
Alert Category: Critical - CPU
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0816
SNMP Trap ID: 40
Automatically notify Support: No
User response:
1.
Make sure that the installed microprocessors are compatible with each other (see Installing a microprocessor and
heat sink for information about microprocessor requirements).
2.
Update the server firmware to the latest level (see Updating the firmware).
3.
(Trained technician only) Replace the incompatible microprocessor. One of the CPUs :
806f0608-1301ffff
[PowerSupplyElementName] has a Configuration Mismatch. (PS Configuration)
Explanation: This message is for the use case when an implementation has detected a Power Supply with a
Configuration Error.
May also be shown as 806f06081301ffff or 0x806f06081301ffff
Severity: Error
Alert Category: Critical - Power
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0104
SNMP Trap ID: 4
Automatically notify Support: No
User response:
1.
Make sure that the power supplies installed are with the same rating or wattage.
2.
Reinstall the power supplies with the same rating or wattage.
806f060d-0400ffff
Array [ComputerSystemElementName] has failed. (Drive 0)
Explanation: This message is for the use case when an implementation has detected that an Array Failed.
May also be shown as 806f060d0400ffff or 0x806f060d0400ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0176
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
1.
Make sure that the SAS cable is connected correctly.
2.
3.
Replace the SAS cable.
516
IBM System x3550 M4 Type 7914: Installation and Service Guide

Advertisement

Table of Contents
loading

Table of Contents