IBM x3550 M4 Type 7914 Installation And Service Manual page 594

Table of Contents

Advertisement

8107021b-0301ffff • 81070301-0301ffff
8107021b-0301ffff
Sensor [SensorElementName] has transitioned to a less severe state from critical. (CPU 1
QPILinkErr)
Explanation: This message is for the use case when an implementation has detected a Sensor transition to less
severe from critical.
May also be shown as 8107021b0301ffff or 0x8107021b0301ffff
Severity: Info
Alert Category: Critical - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0523
SNMP Trap ID: 50
Automatically notify Support: No
User response: No action; information only.
8107021b-0302ffff
Sensor [SensorElementName] has transitioned to a less severe state from critical. (CPU 2
QPILinkErr)
Explanation: This message is for the use case when an implementation has detected a Sensor transition to less
severe from critical.
May also be shown as 8107021b0302ffff or 0x8107021b0302ffff
Severity: Info
Alert Category: Critical - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0523
SNMP Trap ID: 50
Automatically notify Support: No
User response: No action; information only.
81070301-0301ffff
Sensor [SensorElementName] has deasserted the transition to non-recoverable from a less
severe state. (CPU 1 OverTemp)
Explanation: This message is for the use case when an implementation has detected that the Sensor transition to
non-recoverable from less severe has deasserted.
May also be shown as 810703010301ffff or 0x810703010301ffff
Severity: Info
Alert Category: Critical - Temperature
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0525
SNMP Trap ID: 0
Automatically notify Support: No
User response: No action; information only.