806f0028-2101ffff
Sensor [SensorElementName] is unavailable or degraded on management system
[ComputerSystemElementName]. (TPM Cmd Failures)
Explanation: This message is for the use case when an implementation has detected a Sensor is Unavailable or
degraded.
May also be shown as 806f00282101ffff or 0x806f00282101ffff
Severity: Warning
Alert Category: Warning - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0398
SNMP Trap ID: 60
Automatically notify Support: No
User response:
1.
Turn off the server and disconnect the power cords. Reconnect the power cords and restart the server.
2.
If the problem remains, (trained technician only) replace the system board.
806f0107-0301ffff
An Over-Temperature Condition has been detected on [ProcessorElementName]. (CPU 1)
Explanation: This message is for the use case when an implementation has detected an Over-Temperature Condition
Detected for Processor.
May also be shown as 806f01070301ffff or 0x806f01070301ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0036
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure that the fans are operating. There are no obstructions to the airflow (front and rear of the server), the
air baffles are in place and correctly installed, and the server cover is installed and completely closed.
2.
Make sure that the heat sink for microprocessor n is installed correctly.
3.
(Trained technician only) Replace microprocessor n. (n = microprocessor number)
806f0028-2101ffff • 806f0107-0301ffff
Appendix A. Integrated management module II (IMM2) error messages
437