IBM x3550 M4 Type 7914 Installation And Service Manual page 441

Table of Contents

Advertisement

800b030c-2581ffff
Non-redundant:Sufficient Resources from Redundancy Degraded or Fully Redundant for
[RedundancySetElementName] has asserted. (Backup Memory)
Explanation: This message is for the use case when a Redundancy Set has transitioned from Redundancy Degraded
or Fully Redundant to Non-redundant:Sufficient.
May also be shown as 800b030c2581ffff or 0x800b030c2581ffff
Severity: Warning
Alert Category: Warning - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0806
SNMP Trap ID: 43
Automatically notify Support: No
User response:
1.
Check the system-event log for DIMM failure events (uncorrectable or PFA) and correct the failures.
2.
Re-enable mirroring in the Setup utility.
800b0509-1301ffff
Non-redundant:Insufficient Resources for [RedundancySetElementName] has asserted. (Power
Resource)
Explanation: This message is for the use case when a Redundancy Set has transitioned to Non-
redundant:Insufficient Resources.
May also be shown as 800b05091301ffff or 0x800b05091301ffff
Severity: Error
Alert Category: Critical - Redundant Power Supply
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0810
SNMP Trap ID: 9
Automatically notify Support: No
User response:
Power load may be handled by remaining power supply. The system will attempt to throttle to avoid a power
1.
supply over-current condition. But a system shutdown may happen anyway if the power load is too great.
Reduce the total power consumption by removing newly added or unused options like drives or adaptors.
2.
3.
Use the IBM Power Configurator utility to determine current system power consumption. For more information
and to download the utility, go to http://www-03.ibm.com/systems/bladecenter/resources/powerconfig.html.
4.
Replace the power supply with higher rated power.
800b030c-2581ffff • 800b0509-1301ffff
Appendix A. Integrated management module II (IMM2) error messages
423

Advertisement

Table of Contents
loading

Table of Contents