IBM x3550 M4 Type 7914 Installation And Service Manual page 425

Table of Contents

Advertisement

80010b01-1404ffff
Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has
asserted. (DIMM CD VR Temp)
Explanation: This message is for the use case when an implementation has detected an Upper Non-recoverable
sensor going high has asserted.
May also be shown as 80010b011404ffff or 0x80010b011404ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0498
SNMP Trap ID: 0
Automatically notify Support: No
User response: Check the server airflow. Make sure that nothing is blocking the air from coming into or preventing
the air from exiting the server.
80010b01-1405ffff
Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has
asserted. (DIMM EF VR Temp)
Explanation: This message is for the use case when an implementation has detected an Upper Non-recoverable
sensor going high has asserted.
May also be shown as 80010b011405ffff or 0x80010b011405ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0498
SNMP Trap ID: 0
Automatically notify Support: No
User response: Check the server airflow. Make sure that nothing is blocking the air from coming into or preventing
the air from exiting the server.
80010b01-1406ffff
Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has
asserted. (DIMM GH VR Temp)
Explanation: This message is for the use case when an implementation has detected an Upper Non-recoverable
sensor going high has asserted.
May also be shown as 80010b011406ffff or 0x80010b011406ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0498
SNMP Trap ID: 0
Automatically notify Support: No
User response: Check the server airflow. Make sure that nothing is blocking the air from coming into or preventing
the air from exiting the server.
80010b01-1404ffff • 80010b01-1406ffff
Appendix A. Integrated management module II (IMM2) error messages
407

Advertisement

Table of Contents
loading

Table of Contents