806f030c-2012ffff • 806f030c-2013ffff
6.
(Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the
connector contains any foreign material or is damaged, replace the system board.
7.
(Trained service technician only) Remove the affected microprocessor and check the microprocessor socket pins
for any damaged pins. If a damage is found, replace the system board.
8.
(Trained service technician only) If the problem is related to microprocessor socket pins, replace the system
board.
806f030c-2012ffff
Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
(DIMM 18)
Explanation: This message is for the use case when an implementation has detected a Memory Scrub failure.
May also be shown as 806f030c2012ffff or 0x806f030c2012ffff
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0136
SNMP Trap ID: 41
Automatically notify Support: No
User response: Note: Each time you install or remove a DIMM, you must disconnect the server from the power
source; then, wait 10 seconds before restarting the server.
Refer to TIP H212293 for minimum code level.
1.
2.
Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
3.
Make sure that the DIMMs are firmly seated and no foreign material is found in the DIMM connector. Then,
retry with the same DIMM.
4.
If the problem is related to a DIMM, replace the failing DIMM indicated by the error LEDs.
5.
If the problem occurs on the same DIMM connector, swap the affected DIMMs (as indicated by the error LEDs
on the system board or the event logs) to a different memory channel or microprocessor.
6.
(Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the
connector contains any foreign material or is damaged, replace the system board.
7.
(Trained service technician only) Remove the affected microprocessor and check the microprocessor socket pins
for any damaged pins. If a damage is found, replace the system board.
8.
(Trained service technician only) If the problem is related to microprocessor socket pins, replace the system
board.
806f030c-2013ffff
Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
(DIMM 19)
Explanation: This message is for the use case when an implementation has detected a Memory Scrub failure.
May also be shown as 806f030c2013ffff or 0x806f030c2013ffff
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0136
SNMP Trap ID: 41
Automatically notify Support: No
User response: Note: Each time you install or remove a DIMM, you must disconnect the server from the power
source; then, wait 10 seconds before restarting the server.
1.
Refer to TIP H212293 for minimum code level.
Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
2.
478
IBM System x3550 M4 Type 7914: Installation and Service Guide