IBM x3550 M4 Type 7914 Installation And Service Manual page 439

Table of Contents

Advertisement

800b0108-1301ffff
Redundancy Lost for [RedundancySetElementName] has asserted. (Power Unit)
Explanation: This message is for the use case when Redundancy Lost has asserted.
May also be shown as 800b01081301ffff or 0x800b01081301ffff
Severity: Error
Alert Category: Critical - Redundant Power Supply
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0802
SNMP Trap ID: 9
Automatically notify Support: No
User response:
1.
Check the LEDs for both power supplies.
2.
Follow the actions in Power-supply LEDs.
800b010a-1e81ffff
Redundancy Lost for [RedundancySetElementName] has asserted. (Fan Zone 1)
Explanation: This message is for the use case when Redundancy Lost has asserted.
May also be shown as 800b010a1e81ffff or 0x800b010a1e81ffff
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0802
SNMP Trap ID: 11
Automatically notify Support: No
User response:
1.
Make sure that the connectors on fan n are not damaged.
2.
Make sure that the fan n connectors on the system board are not damaged.
3.
Make sure that the fans are correctly installed.
4.
Reseat the fans.
5.
Replace the fans. (n = fan number)
800b010a-1e82ffff
Redundancy Lost for [RedundancySetElementName] has asserted. (Fan Zone 2)
Explanation: This message is for the use case when Redundancy Lost has asserted.
May also be shown as 800b010a1e82ffff or 0x800b010a1e82ffff
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0802
SNMP Trap ID: 11
Automatically notify Support: No
User response:
1.
Make sure that the connectors on fan n are not damaged.
2.
Make sure that the fan n connectors on the system board are not damaged.
3.
Make sure that the fans are correctly installed.
800b0108-1301ffff • 800b010a-1e82ffff
Appendix A. Integrated management module II (IMM2) error messages
421

Advertisement

Table of Contents
loading

Table of Contents