IBM x3550 M4 Type 7914 Installation And Service Manual page 486

Table of Contents

Advertisement

806f030c-2001ffff • 806f030c-2002ffff
806f030c-2001ffff
Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
(DIMM 1)
Explanation: This message is for the use case when an implementation has detected a Memory Scrub failure.
May also be shown as 806f030c2001ffff or 0x806f030c2001ffff
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0136
SNMP Trap ID: 41
Automatically notify Support: No
User response: Note: Each time you install or remove a DIMM, you must disconnect the server from the power
source; then, wait 10 seconds before restarting the server.
1.
Refer to TIP H212293 for minimum code level.
2.
Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
3.
Make sure that the DIMMs are firmly seated and no foreign material is found in the DIMM connector. Then,
retry with the same DIMM.
4.
If the problem is related to a DIMM, replace the failing DIMM indicated by the error LEDs.
5.
If the problem occurs on the same DIMM connector, swap the affected DIMMs (as indicated by the error LEDs
on the system board or the event logs) to a different memory channel or microprocessor.
6.
(Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the
connector contains any foreign material or is damaged, replace the system board.
(Trained service technician only) Remove the affected microprocessor and check the microprocessor socket pins
7.
for any damaged pins. If a damage is found, replace the system board.
(Trained service technician only) If the problem is related to microprocessor socket pins, replace the system
8.
board.
806f030c-2002ffff
Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
(DIMM 2)
Explanation: This message is for the use case when an implementation has detected a Memory Scrub failure.
May also be shown as 806f030c2002ffff or 0x806f030c2002ffff
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0136
SNMP Trap ID: 41
Automatically notify Support: No
User response: Note: Each time you install or remove a DIMM, you must disconnect the server from the power
source; then, wait 10 seconds before restarting the server.
1.
Refer to TIP H212293 for minimum code level.
2.
Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
3.
Make sure that the DIMMs are firmly seated and no foreign material is found in the DIMM connector. Then,
retry with the same DIMM.
4.
If the problem is related to a DIMM, replace the failing DIMM indicated by the error LEDs.
5.
If the problem occurs on the same DIMM connector, swap the affected DIMMs (as indicated by the error LEDs
on the system board or the event logs) to a different memory channel or microprocessor.
468
IBM System x3550 M4 Type 7914: Installation and Service Guide

Advertisement

Table of Contents
loading

Table of Contents