IBM x3550 M4 Type 7914 Installation And Service Manual page 497

Table of Contents

Advertisement

3.
Make sure that the DIMMs are firmly seated and no foreign material is found in the DIMM connector. Then,
retry with the same DIMM.
4.
If the problem is related to a DIMM, replace the failing DIMM indicated by the error LEDs.
5.
If the problem occurs on the same DIMM connector, swap the affected DIMMs (as indicated by the error LEDs
on the system board or the event logs) to a different memory channel or microprocessor.
6.
(Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the
connector contains any foreign material or is damaged, replace the system board.
7.
(Trained service technician only) Remove the affected microprocessor and check the microprocessor socket pins
for any damaged pins. If a damage is found, replace the system board.
8.
(Trained service technician only) If the problem is related to microprocessor socket pins, replace the system
board.
806f030c-2014ffff
Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
(DIMM 20)
Explanation: This message is for the use case when an implementation has detected a Memory Scrub failure.
May also be shown as 806f030c2014ffff or 0x806f030c2014ffff
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0136
SNMP Trap ID: 41
Automatically notify Support: No
User response: Note: Each time you install or remove a DIMM, you must disconnect the server from the power
source; then, wait 10 seconds before restarting the server.
1.
Refer to TIP H212293 for minimum code level.
2.
Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error.
3.
Make sure that the DIMMs are firmly seated and no foreign material is found in the DIMM connector. Then,
retry with the same DIMM.
4.
If the problem is related to a DIMM, replace the failing DIMM indicated by the error LEDs.
5.
If the problem occurs on the same DIMM connector, swap the affected DIMMs (as indicated by the error LEDs
on the system board or the event logs) to a different memory channel or microprocessor.
6.
(Trained technician only) If the problem occurs on the same DIMM connector, check the DIMM connector. If the
connector contains any foreign material or is damaged, replace the system board.
7.
(Trained service technician only) Remove the affected microprocessor and check the microprocessor socket pins
for any damaged pins. If a damage is found, replace the system board.
8.
(Trained service technician only) If the problem is related to microprocessor socket pins, replace the system
board.
Appendix A. Integrated management module II (IMM2) error messages
806f030c-2014ffff
479

Advertisement

Table of Contents
loading

Table of Contents