7.4 TROUBLESHOOTING GUIDE
Table 7-5
PROBLEM
Unable to call Operator 1
Connected terminal (RS-
232C port) does not
operate.
Unable to reconnect when
the line is busy.
Unable to make a no-
response reconnection.
Unable to generate a call
waiting tone from the VPS.
Unable to make Intercom
Paging to groups.
174
Installation Manual
PROBABLE CAUSE
Improper setting of the
operator extension number.
Improper connection.
Improper setting of the RS-
232C parameters.
Improper setting of the busy
signal reconnection procedure.
Improper setting of the no-
response reconnection
procedure.
Improper setting of sequence. •
Improper setting of the
Intercom Paging access code.
POSSIBLE SOLUTION
Adjust the operator extension
number to that of the connected
PBX (see "Operator's
Extension" in Table B-12 in
B5.1 Automated Attendant
Parameters).
Be sure you are using a null
modem cable (see 2.8
TERMINAL CONNECTION).
The terminal and VPS should
have the same parameter
settings for Baud Rate, Word
Bit Length, Parity and Stop Bit
Length (see B7.1 RS-232C
Parameters).
Re-adjust the busy signal
reconnection procedure to that
of the connected PBX (see
"Reconnect Sequence on
Busy" in Table B-42 in B7.3
PBX Interface Parameters).
Re-adjust the no-response
reconnection procedure to that
of the connected PBX (see
"Reconnect Sequence on No
Answer" in Table B-42 B7.3
PBX Interface Parameters).
Adjust the Call Waiting
sequence to that of the
connected PBX (see "Call
Waiting Sequence" in Table B-
42 in B7.3 PBX Interface
Parameters).
Adjust the Intercom Paging
access code to that of the
connected PBX (see "Paging
Code for Group 1-16" and
"Paging Code for All Groups" in
Table B-34 in B6.7 Other
Parameters).