YASKAWA V1000 Quick Start Manual page 70

Ac drive
Hide thumbs Also See for V1000:
Table of Contents

Advertisement

3.5 Control Circuit Wiring
n
Wire Size and Torque Specifications
Select appropriate wire type and size from
crimp ferrules to the wire ends. Refer to
Table 3.9 Wire Size and Torque Specifications (Same for All Models)
Screw
Terminal
Size
MA, MB,
M3
MC
S1-S7, SC,
RP, +V, A1,
A2, AC, HC,
H1, P1, P2,
M2
PC, MP,
AM, AC, S
+, S-, R+, R-,
IG
n
Ferrule-Type Wire Terminations
Crimp a ferrule to signal wiring to improve wiring simplicity and reliability. Use CRIMPFOX
ZA-3, a crimping tool manufactured by PHOENIX CONTACT.
70
Bare Wire Terminal
Tightening
Torque
Applic. wire
N•m
size
(in-lbs)
2
mm
(AWG)
Stranded: 0.25
to 1.5
0.5 to 0.6
(24 to 16)
(4.4 to 5.3)
Single: 0.25 to
1.5
(24 to 16)
Stranded: 0.25
to 1.0
0.22 to 0.25
(24 to 18)
(1.9 to 2.2)
Single: 0.25 to
1.5
(24 to 16)
Figure 3.16 Ferrule Dimensions
YASKAWA ELECTRIC TOEP C710606 47A YASKAWA AC Drive – V1000 Quick Start Guide
Table
3.9. For simpler and more reliable wiring,
Table 3.10
for ferrule terminal types and sizes.
Applic. wire
Recomm.
2
mm
(AWG)
0.75 (18)
0.75 (18)
d1
d2
Ferrule-Type Terminal
Recomm.
size
2
mm
2
mm
(AWG)
(AWG)
0.25 to 1.0
0.5 (20)
(24 to 17)
0.25 to 0.5
0.5 (20)
(24 to 20)
Wire
Type
Shielded
line, etc.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents